Vaillant, Bulex, … heating (myVAILLANT cloud)

Zones as thermostats, hot water and the system of a Vaillant group heating controller (Bulex MiPro Sense, Vaillant sensoCOMFORT, …) through its internet gateway and the brand’s cloud.

In a dashboard file: a connection with "driver": "myvaillant", its settings in config, and what a data source of it reads in that data source’s params (Connections and data sources).

A dashboard with a connection of this driver, named heating, and a tile that reads it. Any number of tiles can read the same connection. In the editor, the values of params are picked from what the connection lists; ids in the example are made up.

{
"schemaVersion": 4,
"connections": {
"heating": {
"driver": "myvaillant",
"config": {
"brand": "bulex",
"email": "you@example.com",
"password": "your password"
}
}
},
"screens": [
{
"name": "Home",
"tiles": [
{
"type": "thermostat",
"label": "Living room",
"layout": { "x": 1, "y": 1, "width": 2, "height": 2 },
"dataSource": {
"connection": "heating",
"params": {
"device": "b1c2d3e4-0000-4000-8000-000000000001/zone/0"
}
}
}
]
}
]
}
Field Type Default What
brand one of bulex, vaillant, sdbg (Saunier Duval), glow-worm, demirdokum (DemirDöküm) Brand. Whose app the account logs in to; Bulex when left out.
country one of albania, austria, belgium, bosnia (Bosnia and Herzegovina), bulgaria, croatia, cyprus, czechrepublic (Czechia), denmark, estonia, finland, france, georgia, germany, greece, hungary, ireland, italy, kosovo, latvia, lithuania, luxembourg, moldavia (Moldova), netherlands, new-zealand, north-macedonia, norway, poland, portugal, romania, serbia, slovakia, slovenia, spain, sweden, switzerland, turkiye (Türkiye), ukraine, unitedkingdom, uzbekistan Country. Where the account is registered; Vaillant and Saunier Duval only.
email text required Email. The login of the brand’s app (MiGo Link, myVAILLANT, …).
password text required Password. Of that login. A credential.
quickVetoHours number, 0.5 to 24 Temporary set point for. Hours, when a zone’s temperature is set on its schedule; 3 when left out.
refreshInterval number, above 0 Refresh every. Seconds; 120 when left out (the cloud limits requests).
Field Type Default What
device text required Device. A zone, the hot water or the system of one of the account’s homes.
value text Value. One of its values; all of them, and a zone as a thermostat, when left out.
refreshInterval number, above 0 Refresh every. Seconds; the connection’s setting when left out.